Aluminium Clad Steel Strand Conductor
-
Refined Matterial
-
Standard Process
-
Free Sample & Test
-
Long Life-circle
Product Details
Applications
Aluminium clad steel strand conductor is used for various voltage level power transmission lines , overhead transmission lines and overhead ground wires. It can also be applied in various special areas with long span length, coastal areas and island as well as other hot and humid regions, salt fog regions and heavily polluted regions where the high corrosion resistance strand is needed. Aluminium clad steel conductor also be used as messenger wire for electrified railways.
Standard Specification
ASTM B416
Code Number |
Area |
No. of wires |
Diameters |
Weight |
Rated Strength |
DC Resistance |
|
mm2 |
wire |
conductor |
kg/km |
kN |
ohm/km |
||
3 No 5 Awg. |
50,32 |
3 |
4,62 |
9,96 |
334,1 |
54,42 |
1.699 |
3 No 6 Awg. |
39 ,00 |
3 |
4,11 |
8,87 |
265,0 |
45,74 |
2.142 |
3 No 7 Awg. |
31,65 |
3 |
3,67 |
7,90 |
210,1 |
38,36 |
2.701 |
3 No 8 Awg. |
25,10 |
3 |
3,26 |
7,03 |
166,7 |
32,06 |
3.406 |
3 No 9 Awg. |
19,90 |
3 |
2,91 |
6,26 |
132,2 |
25,43 |
4.294 |
3 No 10 Awg. |
15,78 |
3 |
2,59 |
5,58 |
104,8 |
20,16 |
5.415 |
7 No 5 Awg. |
117,40 |
7 |
4,62 |
13,90 |
781,1 |
120,27 |
0,7426 |
7 No 6 Awg. |
93,10 |
7 |
4,11 |
12,40 |
619,5 |
101,14 |
0,9198 |
7 No 7 Awg. |
73,87 |
7 |
3,67 |
11,00 |
491,1 |
84,81 |
1.16 |
7 No 8 Awg. |
58,56 |
7 |
3,26 |
9,78 |
389,6 |
70,88 |
1.463 |
7 No 9 Awg. |
46,44 |
7 |
2,91 |
8,71 |
308,9 |
56,20 |
1.844 |
7 No 10 Awg. |
36,83 |
7 |
2,59 |
7,76 |
245,1 |
44,58 |
2.325 |
7 No 11 Awg. |
29,21 |
7 |
2,30 |
6,91 |
194,4 |
35,35 |
2.932 |
7 No 12 Awg. |
23,16 |
7 |
2,05 |
6,16 |
154,2 |
28,03 |
3.697 |
19 No 5 Awg. |
318,70 |
19 |
4,62 |
23,10 |
2129,0 |
326,39 |
0,2698 |
19 No 6 Awg. |
252,70 |
19 |
4,11 |
20,60 |
1688,0 |
274,55 |
0,3402 |
19 No 7 Awg. |
200,40 |
19 |
3,67 |
18,30 |
1339,0 |
230,18 |
0,4290 |
19 No 8 Awg. |
158,90 |
19 |
3,26 |
16,30 |
1062,0 |
192,41 |
0,5409 |
19 No 9 Awg. |
126,10 |
19 |
2,91 |
14,50 |
842,0 |
152,58 |
0,6821 |
19 No 10 Awg. |
99,96 |
19 |
2,59 |
12,90 |
667,7 |
121,00 |
0,8601 |
37 No 5 Awg. |
620,60 |
37 |
4,62 |
32,30 |
4170,0 |
635,43 |
0,1394 |
37 No 6 Awg. |
492,20 |
37 |
4,11 |
28,80 |
3307,0 |
534,85 |
0,1757 |
37 No 7 Awg. |
390,30 |
37 |
3,67 |
25,70 |
2623,0 |
448,09 |
0,2216 |
37 No 8 Awg. |
309,50 |
37 |
3,26 |
22,90 |
2080,0 |
374,67 |
0,2794 |
37 No 9 Awg. |
245,50 |
37 |
2,91 |
20,30 |
1649,0 |
279,11 |
0,3523 |
37 No 10 Awg. |
194,70 |
37 |
2,59 |
17,90 |
1308,0 |
235,61 |
0,4443 |
DIN 48201
Code Number |
Area |
No. of wires |
Diameters(mm) |
Weight |
Rated Strength |
DC Resistance |
|
mm2 |
mm2 |
wire |
conductor |
kg/km |
kN |
ohm/km |
|
25 |
24.25 |
7 |
2.1 |
6.3 |
162 |
31.56 |
3.546 |
35 |
34.36 |
7 |
2.5 |
7.5 |
229 |
44.72 |
2.499 |
50 |
49.48 |
7 |
3 |
9 |
330 |
64.4 |
1.736 |
70 |
65.81 |
19 |
2.1 |
10.5 |
441 |
85.65 |
1.313 |
95 |
93.27 |
19 |
2.5 |
12.5 |
626 |
121.39 |
0.925 |
120 |
116.99 |
19 |
2.8 |
14 |
785 |
152.26 |
0.737 |
150 |
147.11 |
37 |
2.25 |
15.7 |
990 |
191.46 |
0.587 |
185 |
181.62 |
37 |
2.5 |
17.5 |
1221 |
236.38 |
0.476 |
240 |
242.54 |
61 |
2.25 |
20.2 |
1635 |
299.05 |
0.357 |
300 |
299.43 |
61 |
2.5 |
22.5 |
2017 |
369.2 |
0.289 |